NOISE REDUCTION (Wall dividers, folding doors)


NOISE REDUCTION (Wall dividers, folding doors)
The noise reduction wall shall employ a dynamic brake, distinct and separate from the brake in order to lower the wall at a controlled speed
of no more than approximately 150% of the normal down speed, in the case of a catastrophic failure in the power train.

sound_proofing

Skyfold panels for noise reduction shall are architecturally flat
with no bowing, oil canning, warping, waviness or any other surface
deformation and discontinuity.
The noise reduction test made on Skyfold's Autolift Wall System was
conculsive. The sample use had attached to the interior face of each
panel was 38 mm (1.5 in.) thick semi-rigid glass fiber (identified as
Manson AKI boar, density 28.8kg/m2. The noise reduction panels were
hinged at two locations each. In the closed position, there was 13mm
(0.5 in.) overlap between the panels. The panel joints were sealed with
13mm (0.5 in.) by 6 mm (0.25 in.) expanded crossed-linked polyethylene
foam. The panels were sealed to the test frame around the vertical
perimeter using 3 mm (0.125 in.) thick rubber bulb seals which measured
nominally 19 mm (0.75 in.) in the closed position. The noise reduction
panels were sealed tot he test frame around the top and bottom
perimeter using 2 mm (0.08 in.) thick rubber bulb seals which measured
nominally 38 mm (1.5 in.) at the top and 35 mm (1.375 in.) at the
bottom in the closed position. Laboratory personnel performed a full
inspection on the noise reduction test specimen. Prior to testing the
operable wall was opened and closed at least five times, and th test
was conducted with no further adjustments.

keyconsumer.com / gym dividers / NOISE REDUCTION (Wall dividers, folding doors)